1720E Turbidimeter with SC200 Controller, 2 Channel

1720E Turbidimeter with SC200 Controller, 2 Channel
Product #: 2976800-MY
Brand: HACH
Unit Price Contact Hach

Accuracy

Continuously flowing sample flows through the patented* bubble removal system, which vents entrained air from the sample stream and eliminates the most significant interference in low level turbidity measurement. The 1720E Turbidimeter is not affected by variations in flow and pressure.

Simplicity

A simplified two-module design includes the sensor and the controller interface. The controller accepts two turbidity sensors adding a second 1720E sensor makes a system with two complete turbidimeters. Connections are simple plug & play.

Data Collection and Display

The 1720E Turbidimeter uses the SC200 Controller to receive data from up to two sensors. A built-in data logger collects turbidity measurement at user selectable intervals (1-15 minutes), along with calibration and verification points, alarm history, and instrument setup changes for 6 months. Communications using Modbus RS485, MODBUS RS232, HART, or Profibus DP.

USEPA Reporting

Meets and exceeds USEPA Method 180.1 for measuring turbidity for drinking water compliance. One controller accepts up to two plug and play sensors giving you two complete turbidimeters. Sensitive to fine changes in low level turbidity with a built-in bubble removal system.

Experience

The 1720E Turbidimeter reflects 45 years of Hach leadership in turbidity measurement science. Hach has the largest turbidimeter installation base in the world. And, Hach offers a two-year warranty on the 1720E.

What's included?

Hach SC200 Controller, Mounting Hardware, SC200 Basic User Manual, 1720E, 1720E User Manual, and 1000 mL 20 NTU Stablcal . (The controller power cord is ordered separately.)

Specifications

Accuracy: ±2% of reading or ±0.02 NTU (whichever is greater) from 0 - 40 NTU
Accuracy 2: ±5% of reading from 40 - 100 NTU (Defined according to ISO 15839.)
Alarm: When connected to sc controller: three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac
Certifications: Listed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1
Certifications 2: CE certified by Hach Company to EN61326 (industrial levels)
Communication: digital: When connected to sc controller: MODBUS RS232/RS485, PROFIBUS, HART
Compliance Certifications: Standard Methods 2130B, USEPA 180.1, Hach Method 8195
Controller: Dual Digital
Dimensions (H x W x D): 254 mm x 305 mm x 406 mm
Measuring range: 0.001 - 100 Nephelometric Turbidity Units (NTU)
Mounting: Turbidimeter body and head assembly: wall and floor stand; sc controller: wall, pole, panel, and floor stand
Number of Channels: 2
Operating Humidity: 5 - 95 % non-condensing
Operating temperature range: 0 - 40 °C (Double Sensor System)
Operating Temperature Range: 0 - 50 °C (Single Sensor System)
Outputs: Up to five selectable for 0-20 mA or 4-20 mA; output span programmable over any portion of the 0-100 NTU range; built into the sc Controller
Power requirements (Hz): 50 - 60 Hz
Power requirements (Voltage): 115 - 230 VAC
Repeatability: Better than ± 1.0 % of reading or ±0.002 NTU, whichever is greater (Defined according to ISO 15839.)
Response time: Initial response in 1 minute, 15 seconds for a full-scale step change
Sample Flow Rate: 200 - 750 mL/minute (3.1 - 11.9 gal/hour)
Sample Input: 1/4 inch NPT female, 1/4 inch compression fitting (provided)
Sample Output: 1/2 inch NPT female, 1/2 inch hose barb (provided)
Sample Temperature: 0 - 70°C (32 - 122°F)
Ship Wt. (lbs): 1720E Turbidimeter: 5.9 kg (13 lbs.)
Signal Average Time: User selectable from 0, 6, 30, 60, 90 seconds
Storage conditions: -20 to 60 °C (-4 to 140 °F)
Warranty: 12 months
What's included?: Hach SC200 Controller, Mounting Hardware, SC200 Basic User Manual, 1720E, 1720E User Manual, and 1000 mL 20 NTU Stablcal . (The controller power cord is ordered separately.)