*Parameters Measured:
Wind Speed
Wind Direction
Virtual Temperature
Barometric Pressure
Accuracy:
Wind Direction: ±2° RMSE >1.0 m/s
Wind Speed: ±0.2 m/s or ±2 % RMS of reading (whichever is greater) for 0 - 65 m/s - otherwise ±5 %
Virtual Temperature: ±2.0 °C (without heater and without sun exposure or wind > 4 m/s)
Air Pressure: ±1.5 hPa
Ambient Temperature:
-40 - +176 °F (-40 - +80 °C)
Analog Output:
Yes
Analogue Ouput Signal:
4 - 20 mA or 0 - 10 V or 2 - 2000 Hz
Analogue Outputs:
4 - 20 mA or 0 - 10 V
Baud Rate:
1200 - 57600
Bus Operation:
Up to 32 devices
Cable Connection:
8 pole plug
Diameter:
2 in (50 mm)
Dimensions:
Ø approx. 5.9 in (150 mm), height approx. 6.7 in (170 mm)
Factory Certificate:
Yes
Housing Material:
Aluminium, seawater - proof
Interface:
RS485 semi-/full duplex, isolated
IP Rating:
IP68
Measurement technology:
Ultrasonic
Measuring range:
Wind Direction: 0 - 359.9 °
Wind Speed: 0 - 90 m/s
Virtual Temperature: -50 - +70 °C
Air Pressure: 300 - 1200 hPa
Operating Height:
3827 yd (Max) (3500 m)
Operating voltage:
12 - 24 VDC / 1.2 VA (without heating)
24 VDC / 240 VA (140 VA + 100 VA) (with heating)
Product highlights:
Ice-free operation in extreme freezing conditions due to additional transducer heater
Maintenance-free measurement
Suitable for extreme ambient conditions
Vibration and seawater resistant
Compatible interfaces
Resolution:
Data output: 16 bit
Wind Direction: 0.1 °
Wind Speed: 0.1 m/s
Virtual Temperature: 0.1 °C
Air Pressure: 0.1 hPa
Sample Rate:
Instantaneous: 1 - 10 s
Average: 1 - 10 min
System Monitoring & Controls: Local Status Indication:
Heating, sensor failure
Testing:
Jarring Test: According to IEC 60945
Corrosion Test: According to MIL-STD-810 Method 509.3
Ice-free Test: According to MIL-STD-810F Method 521.2
Highly Accelerated Life Test
Transducer Heater:
Yes
Weight:
Approx. 3.6 lbs (1.6 kg)
Wind Speed:
0 - 295 ft/s (0 - 90 m/s)