Chemistries                  603-2779 2080

TrojanUV3000B

TrojanUV3000B
Product #: TROJANUV3000B
Brand: TROJANUV
Unit Price Contact Hach

Flow Pacing Reduces O&M Costs

The System Control Center (SCC) allows the TrojanUV3000B to be flow paced – meaning the UV lamps of individual banks are turned on and off automatically in response to variations in flow rate (based on a flow meter signal). Flow pacing maximizes operating efficiency by matching UV output to requirements and reducing electrical consumption during periods of low flow by turning lamps off.

Advanced, Self-Contained UV Modules

Space-saving, electronic lamp drivers are housed right in the modules, not in separate external cabinets. This minimizes the footprint of the UV system and eliminates the need for air-conditioning. In fact, the lamp drivers are cooled by convection, thereby reducing O&M costs. Each UV module features a UV lamp status indicator for at-a-glance confirmation that all lamps are operating.

Minimal Engineering and Installation Costs

The TrojanUV3000B can be easily retrofitted into existing chlorine contact tanks and effluent channels, and comes pre-tested, pre-assembled and pre-wired to minimize installation costs.

Operator-friendly Maintenance

Lamps are guaranteed for 12,000 hours of operation and can be replaced without tools. Modules are electrically separate, allowing a single module to be removed without disrupting flow or taking the system offline.

Specifications

Channel Configurations: Channel Options: Concrete (by others)
Channel Configurations: Lamp Banks in Series: Up to 3
Channel Configurations: Level Control Device Options: Automatic Level Controller (ALC) or fixed weir
Electrical Requirements: Power Distribution: Power Distribution Centre
Electrical Requirements: Power Distribution Center: -
Electrical Requirements: Power Input: • 120V, single phase
• 208V, 3-phase
• 240V, single phase
Electrical Requirements: Quantity Required: 1 PDC per bank
Enclosure Ratings: Ballast Cooling Method: Convection; no air conditioning or forced air required
Enclosure Ratings: Installation Location: Indoor or outdoor
Enclosure Ratings: Module Frame/Ballast Enclosure: TYPE 6P (IP67)
Enclosure Ratings: System Monitor/Control Center: 304 stainless steel
System Characteristics: Ballast Type: Electronic; non-variable
System Characteristics: Bank Configuration: Up to 20 modules per bank
System Characteristics: Input Power Per Lamp: 87.5 Watts
System Characteristics: Lamp Configuration: Horizontal, parallel to flow
System Characteristics: Lamp Type: Low-pressure
System Characteristics: Module/Bank Frame: -
System Characteristics: Module Configuration: 4, 6 or 8 lamps per module
System Characteristics: Typical Applications: 1 – 5 MGD (158 – 789 m3/hr)
System Monitoring & Controls: Controller: Monitoring and bank control
System Monitoring & Controls: Flow Pacing: Optional
System Monitoring & Controls: Inputs Required: • 4-20 mA flow signal for Flow Pacing
• Local Status Indication
• Lamp Age (hours)
• UV Intensity (mW/cm2)
• Bank Status (on/off)
• Low Intensity Alarm
• Lamp Failure Alarm
System Monitoring & Controls: Remote Alarms: • UV Intensity (4-20 mA)
• Common Alarm (discrete)
System Monitoring & Controls: UV Intensity Monitoring: Optional