Channel Configurations: Channel Options:
Concrete (by others)
Channel Configurations: Lamp Banks in Series:
Up to 3
Channel Configurations: Level Control Device Options:
Automatic Level Controller (ALC) or fixed weir
Electrical Requirements: Power Distribution:
Power Distribution Centre
Electrical Requirements: Power Distribution Center:
-
Electrical Requirements: Power Input:
• 120V, single phase
• 208V, 3-phase
• 240V, single phase
Electrical Requirements: Quantity Required:
1 PDC per bank
Enclosure Ratings: Ballast Cooling Method:
Convection; no air conditioning or forced air required
Enclosure Ratings: Installation Location:
Indoor or outdoor
Enclosure Ratings: Module Frame/Ballast Enclosure:
TYPE 6P (IP67)
Enclosure Ratings: System Monitor/Control Center:
304 stainless steel
System Characteristics: Ballast Type:
Electronic; non-variable
System Characteristics: Bank Configuration:
Up to 20 modules per bank
System Characteristics: Input Power Per Lamp:
87.5 Watts
System Characteristics: Lamp Configuration:
Horizontal, parallel to flow
System Characteristics: Lamp Type:
Low-pressure
System Characteristics: Module/Bank Frame:
-
System Characteristics: Module Configuration:
4, 6 or 8 lamps per module
System Characteristics: Typical Applications:
1 – 5 MGD (158 – 789 m3/hr)
System Monitoring & Controls: Controller:
Monitoring and bank control
System Monitoring & Controls: Flow Pacing:
Optional
System Monitoring & Controls: Inputs Required:
• 4-20 mA flow signal for Flow Pacing
• Local Status Indication
• Lamp Age (hours)
• UV Intensity (mW/cm2)
• Bank Status (on/off)
• Low Intensity Alarm
• Lamp Failure Alarm
System Monitoring & Controls: Remote Alarms:
• UV Intensity (4-20 mA)
• Common Alarm (discrete)
System Monitoring & Controls: UV Intensity Monitoring:
Optional