Chemistries                  603-2779 2080

TrojanUVSwiftSC

TrojanUVSwiftSC
Product #: TROJANUVSWIFTSC
Brand: TROJANUV
Unit Price Contact Hach

Compact Chamber for Installation Flexibility

The efficient chamber can be installed vertically or horizontally, increasing installation options. The lamps and sleeves are fully serviceable from one side – allowing the system to be installed tight to walls, other equipment or piping. The “L-shaped” chamber design is also 40% more efficient than “U-shaped” systems.

The TrojanUVSwiftSC has been validated through microbial testing. Through this testing, performance data has been generated for UV dose delivery to disinfect microorganisms Cryptosporidium, Giardia, and Adenovirus.

Energy Efficient, High-Output Amalgam Lamps

Requires 1/2 to 1/3 fewer lamps to deliver the required dose compared to traditional UV systems using low-pressure lamps.

Robust Sleeve Wiping

The automatic wiping system minimize fouling of the quartz sleeves. The system operates online, reducing downtime.

Specifications

Chamber: Material: 316L stainless steel
Chamber: Materials of Construction: 316L stainless steel
Chamber: Max Fluent Temp °F (°C): 104 (40)
Chamber: Max Operating Pressure PSI (Bar): 150 (10)
Chamber: Sleeve Cleaning Mechanism (Model Dependent): • None
• Manual
• Automatic
Control Panel: Intensity Pacing & SCADA Comm, Optional: Available on some models
Control Panel: Materials of Construction: Painted mild steel (gray)
Control Panel: Rating: Type 12 (IP54)
Control Panel: Remote ON/OFF (24V - 280V) / Analog Output: Standard / 4 optional outputs (model dependent)
Electrical Requirements: Ballast: A02, B03, B04, B06, B08 Electronic, constant output (100% power)
  D03, D06, D12, D18, D30 Electronic, variable output (60 to 100% power)
Electrical Requirements: Standard Voltage: A02 120 V (230 V Europe)
  B03, B04, B06, B08, D03, D06, D12, D18, D30 208 or 240 V, single phase, 2 wire + gnd, 50/60 Hz L-L
Enclosure Ratings: Ballast Enclosures: Type 12 (IP54)
Enclosure Ratings: Installation Location: Indoor
Sensors: Sensors Per Chamber: 1 per 10 lamps, as per DVGW; 1 per chamber, as per USEPA (available on D30)
Sleeve Cleaning System: ActiClean Cleaning System: None, Manual, or Automatic (Model Dependent)
System Characteristics: Ballast Type: Electronic, high-efficiency, constant and variable output (60 to 100% power) depending on model
System Characteristics: Input Power Per Lamp: 125 - 250 Watts
System Characteristics: Lamp Configuration: Horizontal, perpendicular to flow
System Characteristics: Lamp Type: High-efficiency, high-output, low-pressure amalgam
System Characteristics: Module Configuration: 2 to 30 lamps per chamber
System Characteristics: Number of Lamps: 2 to 30 lamps per chamber
System Characteristics: UVT Range: 70% to 98%
System Monitoring & Controls: Controller: Remote ON/OFF (24V - 280V) / Analog Output, Standard / 4 optional outputs (model dependent), Intensity Pacing & SCADA Comm, Optional, (available on some models)