Chamber: Material:
316L stainless steel
Chamber: Materials of Construction:
316L stainless steel
Chamber: Max Fluent Temp °F (°C):
104 (40)
Chamber: Max Operating Pressure PSI (Bar):
150 (10)
Chamber: Sleeve Cleaning Mechanism (Model Dependent):
• None
• Manual
• Automatic
Control Panel: Intensity Pacing & SCADA Comm, Optional:
Available on some models
Control Panel: Materials of Construction:
Painted mild steel (gray)
Control Panel: Rating:
Type 12 (IP54)
Control Panel: Remote ON/OFF (24V - 280V) / Analog Output:
Standard / 4 optional outputs (model dependent)
Electrical Requirements: Ballast:
A02, B03, B04, B06, B08 Electronic, constant output (100% power)
D03, D06, D12, D18, D30 Electronic, variable output (60 to 100% power)
Electrical Requirements: Standard Voltage:
A02 120 V (230 V Europe)
B03, B04, B06, B08, D03, D06, D12, D18, D30 208 or 240 V, single phase, 2 wire + gnd, 50/60 Hz L-L
Enclosure Ratings: Ballast Enclosures:
Type 12 (IP54)
Enclosure Ratings: Installation Location:
Indoor
Sensors: Sensors Per Chamber:
1 per 10 lamps, as per DVGW; 1 per chamber, as per USEPA (available on D30)
Sleeve Cleaning System: ActiClean Cleaning System:
None, Manual, or Automatic (Model Dependent)
System Characteristics: Ballast Type:
Electronic, high-efficiency, constant and variable output (60 to 100% power) depending on model
System Characteristics: Input Power Per Lamp:
125 - 250 Watts
System Characteristics: Lamp Configuration:
Horizontal, perpendicular to flow
System Characteristics: Lamp Type:
High-efficiency, high-output, low-pressure amalgam
System Characteristics: Module Configuration:
2 to 30 lamps per chamber
System Characteristics: Number of Lamps:
2 to 30 lamps per chamber
System Characteristics: UVT Range:
70% to 98%
System Monitoring & Controls: Controller:
Remote ON/OFF (24V - 280V) / Analog Output, Standard / 4 optional outputs (model dependent), Intensity Pacing & SCADA Comm, Optional, (available on some models)