Accuracy:
                                            
                                            
                                        
									    ±2 % plus 0.01 NTU from 0 - 40 NTU; 
±10 % of reading from 40 - 1000 NTU based on Formazin primary standard  (at 25 °C)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Calibration Method:
                                            
                                            
                                        
									    For Formazin and Stablcal: 
20 NTU from 0 - 40 NTU; at 20 FNU and 600 NTU for full range
Custom calibration for up to 6-point calibrations
Degrees 0 - 100 mg/L
SDVB 0 - 1000 NTU
                                    
                                
    						
								
                                    
                                        
                                            
                                                Certifications:
                                            
                                            
                                        
									    CE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Australian ACMA Marking
                                    
                                
    						
								
                                    
                                        
                                            
                                                Communication:
                                            
                                            
                                        
									    Link2sc
                                    
                                
    						
								
                                    
                                        
                                            
                                                Dimensions (H x W x D):
                                            
                                            
                                        
									    195 mm x 409 mm x 278 mm
                                    
                                
    						
								
                                    
                                        
                                            
                                                Display:
                                            
                                            
                                        
									    7" WVGA (800 x 480) colour TFT-LCD with touch screen
                                    
                                
    						
								
                                    
                                        
                                            
                                                Enclosure Construction:
                                            
                                            
                                        
									    PC/ABS Blend Plastic
                                    
                                
    						
								
                                    
                                        
                                            
                                                Light source:
                                            
                                            
                                        
									    Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Model:
                                            
                                            
                                        
									    TU5200 EPA
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating Humidity:
                                            
                                            
                                        
									    80% at 30 °C (non condensing)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating temperature range:
                                            
                                            
                                        
									    10 - 40 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Hz):
                                            
                                            
                                        
									    50/60 Hz
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Voltage):
                                            
                                            
                                        
									    100 - 240 VAC
                                    
                                
    						
								
                                    
                                        
                                            
                                                Range:
                                            
                                            
                                        
									    EPA:
0 - 700 NTU / FNU / TE/F / FTU
0 - 100 mg/L
0 - 175 EBC
ISO:
0 - 1000 NTU / FNU / TE/F / FTU
0 - 100 mg/L
0 - 250 EBC
                                    
                                
    						
								
                                    
                                        
                                            
                                                Regulatory:
                                            
                                            
                                        
									    EPA
                                    
                                
    						
								
                                    
                                        
                                            
                                                Repeatability:
                                            
                                            
                                        
									    <40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
>40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Resolution:
                                            
                                            
                                        
									    0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
                                    
                                
    						
								
                                    
                                        
                                            
                                                Response time:
                                            
                                            
                                        
									    Signal averaging off: 7 seconds
Signal averaging on: 10 seconds (when averaging time is 5 seconds)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Temperature:
                                            
                                            
                                        
									    4 - 70 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Source Lamp:
                                            
                                            
                                        
									    EPA Version - 650 nm Class 2 Laser
                                    
                                
    						
								
                                    
                                        
                                            
                                                Storage conditions:
                                            
                                            
                                        
									    -30 - 60 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Stray Light:
                                            
                                            
                                        
									    <10 mNTU
                                    
                                
    						
								
                                    
                                        
                                            
                                                Units:
                                            
                                            
                                        
									    NTU, FNU, TE/F, FTU, EBC;
mg/L if calibrated with Degrees calibration curve
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    12 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    2.4 kg
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    TU5200 benchtop turbidimeter, user manual, Stablcal kit (10, 20 and 600 NTU), 2 sample vials, power supply, dust cover, vial stand