Chemistries                  603-2779 2080

Intellical LBOD101 Luminescent/Optical Dissolved Oxygen (LDO) Sensor for BOD Measurements, 1 m Cable

Intellical LBOD101 Luminescent/Optical Dissolved Oxygen (LDO) Sensor for BOD Measurements, 1 m Cable
Product #: LBOD10101
Brand: HACH
Unit Price Contact Hach
Available

The Hach Intellical LBOD101 optical dissolved oxygen probe improves confidence in the BOD5 testing procedure by reducing variance and maintenance while increasing stability, accuracy, precision, and efficiency (tests per unit time).

The Intellical LBOD101 probe has no membranes to foul or replace, no electrolyte solution to replenish, and fast, reliable 2-point calibration that stabilizes quickly. Additionally, there is no 30-minute polarization and warm-up time with the LBOD101 probe.

Intellical LBOD101 low maintenance requirements keeps lab down-time to a minimum

The Intellical LBOD101 has no membranes to replace (lower cost of ownership), features a replaceable stirrer assembly and a long-life unique magnetic-based motor that is also replaceable.

Intellical digital probes provide ultimate traceability in measurement history

Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number.

Intellical digital probes can be moved between meters without the need to re-calibrate or re-enter measurement settings

Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters.

What's included?

Intellical LBOD101 Luminescent Dissolved Oxygen (LDO) sensor for BOD measurement, Test certificate, and Basic User Manual.

Specifications

Accuracy: ±0.05 mg/L from 0 to 10 mg/L
  ±0.1 mg/L for greater than 10 mg/L
Cable Length: 1.8 m
Dimensions (D x L) : 15.875 mm x 215 mm
Electrode Type: Luminescent Dissolved Oxygen
  Standard
Length: 215 mm
Method Type: Laboratory: Luminescent Dissolved Oxygen
Parameter: BOD
Pressure accuracy: ±3 mbar (0.3 kPa)
Pressure Resolution: 5 mbar (0.5 kPa)
Product Kit: Model: LBOD101
Accessories Included: None
Range: 0.05 - 20.0 mg/L
1 - 200% saturation
Resolution: 0.01/0.1
Saturation accuracy: ±0.59% of reading
Saturation resolution: 0.1 %
Sensor Cable: 1.8 m
Sensor material: Polycarbonate / ABS
Sensor Type : Lumiphore
Special Features: Integrated stirring system.
Temperature Accuracy: ±0.3 °C
Temperature Range: 0 - 50 °C
Temperature resolution: 0.1 °C
Test requirements: Parameter Needed: BOD
Minimum Sample Depth (mm): 10
Thermistor : ATC
Warranty: 12 months
Weight: 0.22 kg
What's included?: Intellical LBOD101 Luminescent Dissolved Oxygen (LDO) sensor for BOD measurement, Test certificate, and Basic User Manual.