*Parameters Measured:
Road surface temperature
Water film (Height up to 4 mm)
Freezing temperature (for different de-icing materials (NaCl, MgCl, CaCl))
Road condition (dry/damp/wet/ice or snow/moist with salt/wet with salt)
Friction
Ice Percentage
Depth (2 additional depth sensors)
Accuracy:
Road surface temperature: ±0.1 °C (-20 - +20 °C), else ±0.2 °C
Freezing point: ±0.5 °C (0 - -2.5 °C), else ±20 % of average value (at de-icing agent NaCl)
Water film height: for 0.2 - 3 mm better than ±30 %
Cable Connection:
Open wires 0.5 mm²
Cable Length:
50 m
Communication:
SDI-12, RS485-UMB
Connector:
Cable 0,5 mm²
Detectable road conditions:
Dry/moist/wet/moist with salt/wet with salt/ice
Dimensions:
Ø 120 mm, H 50 mm
Height above Absolute Altitude:
3000 m
Interface:
RS485
Baud rate: 2400 - 38400 bit/s (Standard: 19200) or SDI-12
IP Rating:
IP68
Material Enclosures:
Salt , UV resistant modified PTFE
Measurement distance:
in-situ
Measurement technology:
Ice percentage: Conductivity measurement
Water film: Radar measurement
Road sirface temperature: NTC
Measuring range:
Road surface temperature: -40 - +80 °C
Freezing point: -40 - 0 °C
Water film height: 0 - 4 mm
Friction (Grip) [slippery-dry]: 0 - 1
Ice Percentage: 0 - 100 %
Number of Depth Sensors:
1
Number of Depth Temperature Sensors:
1
Number of Related Temperature Sensors:
1
Operating Humidity:
0 - 100 % RH
Operating temperature range:
-40 - +80 °C
Power supply:
9 - 14 VDC, nominal 12 V
Product highlights:
Two part housing design allows easy maintenance/re-calibration
Low energy consumption allows solar operation
Radar principle to measure water film
Resolution:
Road surface temperature: 0,1
Freezing point: 0,1
Water film height: 0,01 mm
Road dampness:
Unit: dry/damp/wet/damp with salt/wet with salt
Slippery road conditions:
Unit: no ice/snow, snow, ice
Standard storage temperature:
-40 - +70 °C (in packaging)
Weight:
Approx. 800 g without cable and without external temperature probe