*Parameters Measured:
Wind Speed
Wind Direction
Virtual Temperature
Barometric Pressure
Accuracy:
Wind Direction: < 3° (> 1 m/s) RMSE
Wind Speed: ±0.3 m/s or ±3% (0 - 35 m/s) ±5% (>35 m/s) RMS
Virtual Temperature: ±2.0 °C (without heater and without sun exposure or wind > 4 m/s)
Air Pressure: ±1.5 hPa
Ambient Temperature:
+25 - +140 °F (-4 - +60 °C) without heating
-40 - +140°F (-40 - +60°C) with heating
Analog Output:
Yes
Analogue Ouput Signal:
4 - 20 mA or 0 - 10 V or 2 - 2000 Hz
Analogue Outputs:
4 - 20 mA or 0 - 10 V
Baud Rate:
1200 - 57600
Bus Operation:
Up to 32 devices
Cable Connection:
8 pole plug
Diameter:
2 in (50 mm)
Dimensions:
Ø approx. 5.9 in (150 mm), height approx. 6.7 in (170 mm)
Factory Certificate:
Yes
Housing Material:
Plastic
Interface:
RS485 semi-/full duplex, isolated
IP Rating:
IP66
Measurement technology:
Ultrasonic
Measuring range:
Wind Direction: 0 - 359.9 °
Wind Speed: 0 - 90 m/s
Virtual Temperature: -50 - +70 °C
Air Pressure: 300 - 1200 hPa
Operating Height:
3827 yd (Max) (3500 m)
Operating voltage:
24 VDC ±10 % or 24 VDC/1.2 VA (without heating 12 VDC)
24 VDC, max. 20 VA / 12 V (with heating)
Product highlights:
Maintenance-free measurement
Suitable for extreme ambient conditions
Ice-free operation
Compatible interfaces
Resolution:
Data output: 16 bit
Wind Direction: 0.1 °
Wind Speed: 0.1 m/s
Virtual Temperature: 0.1 °C
Air Pressure: 0.1 hPa
Sample Rate:
Instantaneous: 250 ms; 1-10 s
Average: 1 - 10 min
System Monitoring & Controls: Local Status Indication:
Heating, sensor failure
Transducer Heater:
No
Weight:
Approx. 1.8 lbs (0.8 kg)
Wind Speed:
0 - 246 ft/s (0 - 75 m/s)